Blast Effects on an Air-cleaning System
Richard Dennis
Charles E. Billings
出版
AEC Technical Information Service Extension
, 1957
URL
http://books.google.com.hk/books?id=PioBTqQApXwC&hl=&source=gbs_api
EBook
FULL_PUBLIC_DOMAIN
註釋
Objectives of this project were (1) to determine the effects of blast on filtration devices and typical gas-cleaning systems in the 3- and 1-psi overpressure range, (2) to measure dust dislodged from AEC filters and dry plates by blast and reentrained in reverse-flow air, (3) to determine the pressure attenuation and dust-recovery characteristics of typical wire-mesh viscous filters and dry Fiberglas filters, (4) to determine the natural damping effect of duct work and stacks, and (5) to compare field and laboratory data to determine if present and future laboratory tests can be extrapolated to predict field conditions. Test results showed no damage to AEC filters and only minor damage to Fiberglas filters. Total reentrainment ranged from 73 per cent of total AEC filter loading (3.4-psi area) to 53 per cent (1.5 psi). Dry plates lost 95 per cent of their original dust holding.