登入
選單
返回
Google圖書搜尋
BEAM PIPE DESORPTION RATE IN RHIC.
W. FISCHER
Hanson Huang
J. WEI
D. TRBOJEVIC
V. PTITSYN
U. IRISO
H. C. HSEUH
P. HE
S. Y. YANG
出版
Brookhaven National Laboratory
, 2006
URL
http://books.google.com.hk/books?id=lEV8nQAACAAJ&hl=&source=gbs_api
註釋
In the past, an increase of beam intensity in RHIC has caused several decades of pressure rises in the warm sections during operation. This has been a major factor limiting the RHIC luminosity. About 430 meters of NEG coated beam pipes have been installed in the warm sections to ameliorate this problem. Beam ion induced desorption is one possible cause of pressure rises. A series beam studies in RHIC has been dedicated to estimate the desorption rate of various beam pipes (regular and NEG coated) at various warm sections. Correctors were used to generate local beam losses and consequently local pressure rises. The experimental results are presented and analyzed in this paper.