Prognostic Impact and Diagnostic Value of Invasively Derived Hemodynamic Measures in Patients with Severe Aortic Stenosis Undergoing TAVI
David Grundmann
Alina Goßling
Lennard Schmidt
Lisa Voigtlaender
Sebastian Ludwig
Matthias Linder
Lara Waldschmidt
Till Joscha Demal
Oliver Daniel Bhadra
Andreas Schaefer
Hermann Reichenspurner
Stefan Blankenberg
Lenard Conradi
Dirk Westermann
Moritz Seiffert
Niklas Schofer
出版
Universität
, 2023
URL
http://books.google.com.hk/books?id=wS0H0AEACAAJ&hl=&source=gbs_api
註釋
Abstract: Background
Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI).
Aim
We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI.
Methods
A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed.
Results
In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT CD (1-year mortality: ET ≥ vs. CD: 15.01vs. 33.1%, AT ≥ vs CD 16.3 vs. 26.5%, p